300mm Wide 600mm High Flat Chrome Towel Radiator
- Size
- 300 × 600mm (W × H)
- Pipe centres
- 250mm
- Finish
- Chrome
- Listed output
- 626 BTU/h · 185 W
Available to order
£53.99Inc. VATRadiator only · valves extra
View sizes & options
Quick facts & technical summary
Compare the current 300mm chrome towel radiators and 300mm matt black towel radiators. For the complete fitted arrangement, browse radiator valves and pipe covers, reducers and other accessories.
A 300mm rail offers a useful middle step between extremely narrow 200–250mm models and a wider bathroom radiator, provided the installed fittings fit the available wall. It can work beside a vanity unit, in an en-suite or downstairs cloakroom, but room heating, towel access and door movement still need separate checks.
Use the body width to shortlist the position, then test the complete installation. A rail that fits an empty strip of wall may become awkward when a bath towel hangs across a valve or an opening cupboard door reaches the brackets.
This guide covers Cheap Radiator’s UK range and practical selection checks. The commercial category pages show current prices, valve options and availability; there is no assumption that every height or finish is in stock at the time you order.
The table links particular 300mm chrome models, keeping the connection centres visible while showing how the available vertical space changes the shortlist. Listed heat outputs belong to those exact products and must be assessed at the appropriate system temperatures; a room suggestion is not a guarantee that the radiator will cover its heat loss.
| Height | Pipe centres | Listed output | Possible use | Finish comparison |
|---|---|---|---|---|
| 400mm high | 250mm | 342 BTU/h approximately 100W, converted | Compact hand-towel position | Chrome only in this comparison |
| 600mm high | 250mm | 626 BTU/h 185W listed | Cloakroom or restricted height | Chrome; compare exact black model separately |
| 800mm high | 250mm | 847 BTU/h 249W listed | En-suite with extra hanging space | Chrome; compare exact black model separately |
| 1000mm high | 250mm | 945 BTU/h 278W listed | More vertical space beside a vanity | Chrome; compare exact black model separately |
| 1200mm high | 250mm | 1,284 BTU/h 376W confirmed | Taller drying area on a narrow wall | Chrome; compare exact black model separately |
| 1400mm high | 250mm | 1,445 BTU/h 424W listed | Taller wall with reachable towel slots | Chrome; compare exact black model separately |
| 1600mm high | 250mm | 1,822 BTU/h 534W listed | Tall wall; check reach and fitting dimensions | Chrome; compare exact black model separately |
| 1800mm high | 250mm | 1,822 BTU/h 534W listed | Very tall position; check reach | Chrome; compare exact black model separately |
| 2000mm high | 250mm | 1,983 BTU/h 581W listed | Very tall wall; currently unavailable | Chrome only in this comparison |
The 300 × 1200mm chrome rating is 1,284 BTU/h (376W), confirmed by the business. For other models, use the linked declared wattage rather than converting a rounded BTU figure and treating the result as a separately tested value.
The 1600mm row selects the current 26-tube model, not the older 1600mm listing with different brackets and output. The 2000mm entry explains the catalogue range, not an availability promise; live product cards below show current prices and stock.
Body width, radiator connection centres and wall projection describe three different checks, so none can stand in for the others when planning a tight position. The linked 400–1400mm chrome rails list 75–95mm wall-to-pipe-centre distance and 90–110mm total projection, while older tall models list 70–85mm and 85–100mm respectively.
The selected 1600mm model lists 75–95mm and 90–110mm, whereas the linked 1800mm and 2000mm chrome models list 70–85mm and 85–100mm. Keep the exact model reference with the drawing; do not carry dimensions from one height across the whole range.
For side clearance, begin with 300mm plus the left and right valve projections. Two 40mm projections make 380mm before any extra access allowance; the 300mm fitted-width and wall-clearance guide shows how to test that envelope against furniture and door swings.
Straight valves commonly suit aligned pipes rising from the floor into downward-facing radiator connections, while angled and corner arrangements can suit wall-fed pipes when their drawings match the required orientation. Check where each valve head will sit and how it can be operated, because the name alone does not establish the smallest fitted footprint.
A suitable corner valve may tuck its control closer to the wall than a particular angled alternative, helping in a narrow walkway. It can also move the control into a different obstruction, so compare the complete union, head and pipe entry against the measured position.
Ask the installer about compatible reducers for 8mm or 10mm microbore pipework. Covers and caps finish visible pipes; they do not convert an unsuitable connection. See the valve-orientation guide before choosing the package.
The correct heating choice depends on the bathroom’s design heat loss and the chosen model’s output at the water temperatures the system will actually use. Extra height usually provides more surface area within a comparable design, but insulation, glazing, ventilation and towels covering the bars all affect whether the room will feel adequately heated.
Start with the BTU calculator and confirm the result with the installer. A small cloakroom might be served by a suitable narrow rail alone; a larger bathroom may need a separate emitter or underfloor heating, leaving the rail primarily for towels.
Matt black powder coating generally has higher radiant emissivity than polished chrome at the same surface temperature. Total radiator output also includes convection and depends on construction, so compare the exact declared ratings under matching conditions rather than applying a blanket percentage uplift to black.
A radiator rated at ΔT50 will supply less heat when the mean water-to-room temperature difference falls to ΔT30, as can happen on a lower-temperature heating system. An illustrative correction with an exponent of 1.3 gives about 51.5% of the ΔT50 output, although the manufacturer’s own correction data should govern the final design.
ΔT is a temperature difference, not the boiler flow temperature alone. As an illustration, a verified 945 BTU/h ΔT50 rating would become roughly 487 BTU/h at ΔT30 under that assumption; the calculation does not verify the published model’s original test conditions.
Ask for the exact rating basis before applying any correction. Our narrow-rail heat-output guide and ΔT50-versus-ΔT30 guide explain the checks needed before treating a catalogue figure as usable room heat.
The usable span between the uprights is smaller than the 300mm overall body width, so test your folded towel against that inner space rather than the size label. Hand towels are easier to accommodate, while bath towels and bath sheets generally need folding or hanging vertically instead of being spread flat across a narrow rail.
Try the towel’s actual folded width and drop on a simple wall template. Check that the lower edge stays clear of the valves and floor, and that the intended user can reach the chosen towel slots without stretching or climbing.
A move from 250mm to 300mm adds 50mm of body width; stepping to 350mm adds another 50mm and changes radiator centres again. Compare 300mm and 350mm fitted layouts alongside the 250mm buying guide before deciding which compromise suits the room.
The range uses low-carbon mild steel with standard UK ½-inch BSP bottom connections, an 8-bar factory pressure test and a stated 110°C maximum operating temperature confirmed by the business. Those figures do not establish a safe working pressure or justify running a domestic installation at its temperature limit; use the exact manufacturer’s operating instructions.
Full wall brackets, an air vent and a blanking plug are supplied with the linked examples. Check any additional caps and fixing contents on the selected product; a supplied masonry plug is not automatically suitable for a hollow wall.
Studs, timber noggins or a suitably specified cavity-fixing system may be needed to support the water-filled rail, fittings and towels. The installer must assess the actual wall, check concealed services and follow the bracket arrangement; a towel rail is not a grab rail.
A ½-inch BSP connection makes an element mechanically possible in some radiators, but does not establish approval for electric-only or dual-fuel operation. Confirm the exact rail, element power and insertion length, filling arrangement and expansion provision with the supplier and installers, rather than selecting a wattage solely because the radiator is 300mm wide.
There is no universal 100–150W element recommendation for this width or height range. A T-piece changes the connection arrangement; it does not prove that the element will fit or that a sealed system will be safe. Read the electric and dual-fuel conversion checklist before buying components.
A registered electrician should assess BS 7671 bathroom zones, RCD protection, isolation and the manufacturer’s instructions. Zones 1 and 2 generally need at least IPX4, or IPX5 where water jets are expected, but an IP rating is only one part of installation suitability.
A basin does not create a universal numbered bathroom zone on its own, and outside zones does not mean unrestricted placement. Hardwiring and any fused-spur arrangement must be properly assessed; Part P and notification requirements depend on the work and UK jurisdiction.
Before ordering, write down the exact model, finished wall dimensions, radiator centres and complete valve footprint, then compare its heating output with the room requirement. Check towel reach, the water-filled load and any electrical restrictions with the relevant installer, and use the live product page to confirm the finish, valve choice and current availability.
Radiators carry a 5-year warranty; valves and heating elements carry a 1-year warranty, subject to the applicable terms and without limiting statutory rights. Warehouse support and collection are available by arrangement at Unit 6, Hales Industrial Park, Coventry, CV6 6AT; confirm readiness before travelling.
These six supporting guides let you examine the fitted wall space, neighbouring width choices, heating performance and installation details separately before returning to the complete selection checklist. The clearance guide focuses on the 300mm range, while the established comparison, heat-output, conversion, wall-fixing and finish articles provide context shared with other narrow widths.
Compare the current 300mm chrome towel radiators and 300mm matt black towel radiators. For the complete fitted arrangement, browse radiator valves and pipe covers, reducers and other accessories.
The linked 300mm ladder towel radiators have 250mm between the centres of their bottom radiator connections, rather than 300mm between the inlets. Existing pipework still needs checking with the selected valve dimensions, because radiator connection centres alone do not describe the complete assembled distance or route of the heating pipes.
Allow for the 300mm body plus the actual valves, their operating space and the towel, with clearance from doors, furniture and skirting boards. If fittings project 30–50mm beyond each side, the illustrative fitted width is 360–400mm, but the chosen valve drawings and installer’s measurements must settle the final space requirement.
A 300mm rail can be the main heat source only when its output at the intended water temperatures meets the room’s calculated heat loss. A taller model may offer more output and hanging space, while larger or colder bathrooms may need another radiator or underfloor heating alongside the towel rail.
A 300mm radiator can be fitted to a suitable stud or plasterboard wall when its structure and fixings support the filled rail, fittings and towels. Ask the installer to assess studs, timber noggins or an approved cavity-fixing system, rather than assuming ordinary masonry wall plugs are appropriate for plasterboard.
Electric-only or dual-fuel use depends on approval of the exact radiator, heating element and installation arrangement, including insertion length, wattage, filling and expansion provision. A standard ½-inch BSP connection or a T-piece is not proof of suitability, so confirm compatibility and follow the manufacturer’s instructions before ordering electrical components.
A registered electrician must assess the position, equipment and circuit against BS 7671, the product instructions and applicable Building Regulations before installation. Bathroom zones 1 and 2 generally need at least IPX4 protection, or IPX5 where water jets are expected, but an IP rating alone does not approve the proposed installation.
Choose the widest body that leaves adequate fitted valve clearance and a usable route past doors and furniture, rather than filling the entire measured gap. These ranges use 200mm, 250mm and 300mm connection centres respectively, so changing width also changes pipe positions and may require plumbing alterations as well as extra hanging space.
Huseyin Aras is a UK bathroom heating and product sourcing specialist with more than 18 years of hands-on experience advising customers and installers on radiator selection and fittings. This Cheap Radiator guide uses the current catalogue, business-confirmed range information and the technical references below to help buyers ask precise questions before ordering or commissioning installation.
Catalogue dimensions and linked product outputs were checked on 18 November 2026, with the 1200mm chrome output and range test information confirmed by the business. Product instructions and manufacturer correction data still take precedence for the exact installation, while the references below explain electrical safety, building requirements and lower-temperature heating principles.
Compare live 300mm chrome examples in 600, 800 and 1000mm heights. Confirm the current price, valve options, heat output and installation requirements on each product page.

Available to order
£53.99Inc. VATRadiator only · valves extra
View sizes & options
Available to order
£61.99Inc. VATRadiator only · valves extra
View sizes & options
Available to order
£77.99Inc. VATRadiator only · valves extra
View sizes & optionsPrices and availability come from the current catalogue. Examples may differ in height and output. Check the exact model’s full specification, rating conditions and installation suitability before choosing.